Worcester Bosch Greenstar HE 25 27 28 30 RD428 RD532 Boiler Pump 8737710972

3 left
FROM £169.99
Brand:
WORCESTER
Category:
Pumps
SKU:
N9299
Services
Black Friday deal-10%Ends midnight Mon 30 Nov
£169.99
Exc. VAT £141.65
Black Friday price, no code needed
Same day dispatch 1 year warranty

Worcester Bosch Greenstar HE 25 27 28 30 RD428 RD532 Boiler Pump 8737710972

Product Overview

The Worcester Bosch Greenstar Boiler Circulation Pump (Part Number: 8737710972) is an electrically operated hydraulic component designed to circulate water within suitable Worcester Bosch gas-fired boiler systems.

The pump forms part of the boiler's primary heating circuit, maintaining water circulation through the heat exchanger and associated hydraulic components.

By circulating heated water throughout the system, the pump supports effective heat transfer, temperature regulation and consistent boiler operation.

Working alongside the boiler's electronic controls, temperature sensors and hydraulic components, the circulation pump helps maintain the water flow required during normal appliance operation.

ℹ️ Product Condition Options:

This part may be available in New or Refurbished condition. Please select your desired option from the dropdown menu above. Refurbished circulation pumps should be professionally inspected and tested to confirm correct electrical operation, mechanical performance and hydraulic functionality before installation.

Technical Insight & Common Failure Symptoms

The Worcester Bosch Greenstar circulation pump is an electrically driven component responsible for maintaining water flow through the boiler's primary heating circuit.

The pump supports the transfer of heat generated by the burner into the heating system. Insufficient water circulation may cause rapid temperature increases within the boiler, potentially activating its protective controls.

Electrical faults, worn motor bearings, restricted impeller movement or accumulated deposits may interfere with normal pump operation and reduce circulation performance.

Possible symptoms that may indicate a circulation pump or associated component problem include:

  • Boiler failing to circulate heated water correctly.

  • Radiators remaining cold or heating unevenly.

  • Boiler temperature rising rapidly during operation.

  • Unusual humming, grinding or rattling noises from the pump.

  • Intermittent or inconsistent central heating operation.

  • Pump failing to start when required.

  • Boiler overheating or entering a safety lockout.

  • Reduced heating performance due to insufficient circulation.

  • Water leakage around the pump housing or hydraulic connections.

  • Visible damage or deterioration affecting the pump or its electrical connections.

These symptoms do not necessarily confirm a faulty circulation pump, as similar problems may result from trapped air, blocked filters, restricted heat exchangers, incorrect system pressure, electrical wiring faults or other boiler control and hydraulic components. Correct professional diagnosis should be carried out before replacing the unit.

Safety Advice

Installation and servicing must be carried out by a suitably qualified engineer. Always isolate the electrical supply, allow the boiler to cool and follow the manufacturer's instructions.

Ensure correct pump compatibility, secure electrical and hydraulic connections, and complete the required leak, circulation and boiler safety checks before returning the appliance to service.

This part fits the following boilers:

Fits Appliance(s)
GC No.
Worcester GREENSTAR 28 HE SYSTEM NG
47-108-05
Worcester GREENSTAR CC1 FSN 29KW CB NG
41-108-02
Worcester GREENSTAR CS1 FSN 28KW SYS NG
47-311-74
Worcester GREENSTAR HE 25 COMBI NG
47-311-77
Worcester GREENSTAR HE 30 COMBI NG
41-311-62
Worcester GREENSTAR HE R25 COMBI NG
47-311-78
Worcester GREENSTAR HE R28 SYSTEM NG
41-108-13
Worcester GREENSTAR R30 HE COMBI NG
Worcester GRNSTAR HE FSN ZB 27KW SYS NG
Worcester GSTAR HE FSN GB 27KW COMBI NG
Worcester RD SERIES RD428 SYSTEM NG
Worcester RD SERIES RD532 COMBI NG

Delivery

Free UK delivery is available on orders over £50. Delivery estimates and available services are shown at checkout. Timed and Saturday services may cost extra.

Orders placed before 3 PM are usually dispatched the same working day.

Delivery times may vary for remote areas, Highlands, islands, and non-mainland UK destinations.

If you need urgent delivery help, please contact our customer service team before placing your order.

All Orders First 30 Days:

You can return or cancel your orders for any reason at any time within 30 days of receipt. After 30 days, we reserve the right to charge a restocking fee or refuse the return.

Parts must be returned in the same condition and packaging as received, or we may deduct a percentage of the cost of the part.

A full refund or exchange will be agreed once the item(s) have been received and inspected to ensure they are unused and in their original packaging where applicable.

If the part is returned as faulty and is found to be working upon inspection, postage costs will be deducted from the refund.

Faulty Items After 30 Days:

All items come with a 1 year HTS warranty from the date of purchase. Warranty means HTS will repair or replace the item.

Refunds:

Our returns team will process your refund after we receive and check your items. Please allow up to 15 days for your refund to be processed.

The refund will be made to the original payment method used to place the order.

Contact Us:

For any queries, email us at returns@heatingtradesupplies.com or call +44 01912633708.

Customer Services
National Boiler Spares Ltd
Tyne View Terrace
Wallsend
Tyne and Wear
NE28 6SG

Payment methods
  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Klarna
  • Maestro
  • Mastercard
  • PayPal
  • Shop Pay
  • Union Pay
  • Visa