Product Overview

The Potterton Performa 24 Eco HE / Main Combi 24 HE Printed Circuit Board (Part Number: 5112657) is an electronic control component designed to manage and supervise essential operating functions in compatible gas-fired boiler systems.

The Printed Circuit Board (PCB) forms part of the boiler's main electronic control system, coordinating central heating, domestic hot water, ignition and safety-related operations.

The PCB processes signals from connected temperature sensors, thermostats and safety devices, allowing the boiler to respond to heating and hot water demands.

Working alongside the boiler's ignition equipment, gas valve and hydraulic components, the circuit board supports controlled burner operation, temperature regulation and normal boiler functionality.

ℹ️ Product Condition:

This part is supplied in Brand New condition. Please verify the manufacturer part number and boiler compatibility before purchasing or arranging installation.

Technical Insight & Common Failure Symptoms

The Potterton and Main 5112657 printed circuit board is an electronic control unit responsible for coordinating the boiler's heating, domestic hot water and combustion control functions.

The PCB receives signals from connected sensors and operating controls, processes heating demands and manages the activation of associated boiler components. It also monitors safety-related conditions and can interrupt boiler operation when the required operating conditions are not satisfied.

Electrical faults, damaged connections, moisture exposure or deterioration of internal electronic components may interfere with normal boiler operation.

Possible symptoms that may indicate a printed circuit board or associated component problem include:

  • Boiler failing to start despite receiving a heating demand.

  • Boiler failing to ignite or complete its ignition sequence.

  • Intermittent or unexpected boiler shutdowns.

  • Repeated boiler lockouts or fault indications.

  • Central heating or domestic hot water failing to operate correctly.

  • Boiler failing to respond to thermostat or control signals.

  • Incorrect or intermittent operation of connected boiler components.

  • Unresponsive or irregular boiler control functions.

  • Visible damage, corrosion or deterioration affecting the PCB or its electrical connections.

These symptoms do not necessarily confirm a faulty printed circuit board, as similar problems may result from defective sensors, ignition components, electrical wiring, thermostats, gas valves or other boiler control and safety devices. Correct professional diagnosis should be carried out before replacing the unit.

Safety Advice

Installation and servicing must be carried out by a suitably qualified Gas Safe registered engineer. Always isolate the gas and electrical supplies and follow the manufacturer's instructions.

Ensure correct PCB compatibility, secure electrical connections and complete the required electrical safety, ignition and boiler operational checks before returning the appliance to service.

This part fits the following boilers:

Fits Appliance(s)
GC No.
Potterton Boiler Spares 80 ECO COMBI NG
47-393-11
Potterton Boiler Spares HE 24 COMBI LPG
Potterton Boiler Spares HE 24 COMBI NG
Potterton Boiler Spares PERFORMA 24 COMBI LPG
Potterton Boiler Spares PERFORMA 24 COMBI NG
Potterton Boiler Spares PERFORMA 24 ECO HE COMBI NG

Delivery

Free UK delivery is available on orders over £50. Delivery estimates and available services are shown at checkout. Timed and Saturday services may cost extra.

Orders placed before 3 PM are usually dispatched the same working day.

Delivery times may vary for remote areas, Highlands, islands, and non-mainland UK destinations.

If you need urgent delivery help, please contact our customer service team before placing your order.

All Orders First 30 Days:

You can return or cancel your orders for any reason at any time within 30 days of receipt. After 30 days, we reserve the right to charge a restocking fee or refuse the return.

Parts must be returned in the same condition and packaging as received, or we may deduct a percentage of the cost of the part.

A full refund or exchange will be agreed once the item(s) have been received and inspected to ensure they are unused and in their original packaging where applicable.

If the part is returned as faulty and is found to be working upon inspection, postage costs will be deducted from the refund.

Faulty Items After 30 Days:

All items come with a 1 year HTS warranty from the date of purchase. Warranty means HTS will repair or replace the item.

Refunds:

Our returns team will process your refund after we receive and check your items. Please allow up to 15 days for your refund to be processed.

The refund will be made to the original payment method used to place the order.

Contact Us:

For any queries, email us at returns@heatingtradesupplies.com or call +44 01912633708.

Customer Services
National Boiler Spares Ltd
Tyne View Terrace
Wallsend
Tyne and Wear
NE28 6SG

Payment methods
  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Klarna
  • Maestro
  • Mastercard
  • PayPal
  • Shop Pay
  • Union Pay
  • Visa