GLOWWORM XTRAMAX 96 PRESSURE RELIEF VALVE PRV 05722800 57228

IN STOCK
FROM £14.25
Brand:
Glowworm
Category:
Auto Air Vents, Pressure Relief & Safety Valves
Condition:
New
SKU:
N5284
Condition
New
Service
£14.25
Exc. VAT £11.87
Halloween price · 10% off until 31 Oct
Same day dispatch 1 year warranty

Glow-worm Xtramax 96 Boiler Pressure Relief Valve PRV 05722800 57228

Product Overview

The Glow-worm Xtramax Boiler Pressure Relief Valve (PRV) (Part Numbers: 05722800 / 57228) is a replacement safety component designed for selected Glow-worm heating systems.

Part number 57228 is identified in the manufacturer's technical documentation as a Central Heating Safety Valve.

The Pressure Relief Valve forms part of the boiler's sealed central heating circuit, protecting the system against excessive pressure by allowing water to discharge when the specified pressure limit is reached.

Correct operation of this safety component is important for maintaining safe pressure conditions within the heating system.

ℹ️ Product Condition Options:

This part may be available in New or Refurbished condition. Please select your desired option from the dropdown menu above. Any refurbished safety valve must be professionally assessed and tested to confirm that it meets the required operating specifications before installation.

Technical Insight & Common Failure Symptoms

The Pressure Relief Valve is a mechanical safety device designed to protect the boiler's central heating circuit against excessive pressure.

Under normal operating conditions, the valve remains closed. If system pressure exceeds its specified relief setting, the valve opens to discharge water through the safety discharge pipe.

Over time, the valve may experience sealing deterioration, internal contamination or wear, particularly following repeated operation.

Possible symptoms that may indicate a Pressure Relief Valve or associated system problem include:

  • Water dripping or discharging from the pressure relief pipe.

  • Boiler pressure dropping after water has been discharged.

  • Continuous leakage from the valve outlet.

  • Pressure Relief Valve failing to reseal correctly.

  • Repeated discharge caused by excessive system pressure.

  • Difficulty maintaining normal central heating system pressure.

  • Visible corrosion, damage or deterioration around the valve.

These symptoms do not necessarily confirm a faulty Pressure Relief Valve, as similar problems may result from expansion vessel faults, excessive filling pressure or other heating system components. Correct professional diagnosis should be carried out before replacement.

Compatibility

This part (MPN: 05722800 / 57228) is identified for selected Glow-worm Xtramax boiler systems, including the Xtramax 96.

Please verify the boiler model, part number, valve pressure rating and connection arrangement against the manufacturer's technical documentation before ordering to ensure correct fitment.

Safety Advice

Boiler Pressure Relief Valves are safety-critical components within a pressurised heating system and should only be inspected, removed or installed by a suitably qualified and competent heating engineer.

Always isolate the appliance and allow the heating system to cool before carrying out any work. The system must be safely depressurised in accordance with the manufacturer's servicing instructions. Never block or restrict the safety discharge pipe. The correct valve pressure rating must be maintained, and appropriate pressure, leakage and operational safety checks must be completed before the boiler is returned to service.

This part fits the following boilers:

Fits Appliance(s)
GC No.
Glowworm Xtrafast 120
47-047-26
Glowworm Xtrafast 2000
47-920-44
Glowworm Xtrafast 96
47-047-25
Glowworm Xtramax
47-047-15
Saunier Duval ISOFAST F 28 E
47-920-28
Saunier Duval ISOFAST F28E COMBI NG
-
Saunier Duval ISOMAX F 28 E
-
Saunier Duval ISOMAX F 28 E2 AFTER 04001970
-
Saunier Duval ISOMAX F 28 E2 BEFORE 04001970
-
Saunier Duval XTRAFAST 120 COMBI NG
-
Saunier Duval XTRAFAST 96 COMBI NG
-

Delivery

Free next day UK delivery is available on orders over £50.

Orders placed before 3 PM are usually dispatched the same working day.

Delivery times may vary for remote areas, Highlands, islands, and non-mainland UK destinations.

If you need urgent delivery help, please contact our customer service team before placing your order.

All Orders First 30 Days:

You can return or cancel your orders for any reason at any time within 30 days of receipt. After 30 days, we reserve the right to charge a restocking fee or refuse the return.

Parts must be returned in the same condition and packaging as received, or we may deduct a percentage of the cost of the part.

A full refund or exchange will be agreed once the item(s) have been received and inspected to ensure they are unused and in their original packaging where applicable.

If the part is returned as faulty and is found to be working upon inspection, postage costs will be deducted from the refund.

Faulty Items After 30 Days:

All items come with a 1 year HTS warranty from the date of purchase. Warranty means HTS will repair or replace the item.

Refunds:

Our returns team will process your refund after we receive and check your items. Please allow up to 15 days for your refund to be processed.

The refund will be made to the original payment method used to place the order.

Contact Us:

For any queries, email us at returns@heatingtradesupplies.com or call +44 01912633708.

Customer Services
National Boiler Spares Ltd
Tyne View Terrace
Wallsend
Tyne and Wear
NE28 6SG

Payment methods
  • American Express
  • Apple Pay
  • Diners Club
  • Discover
  • Google Pay
  • Klarna
  • Maestro
  • Mastercard
  • PayPal
  • Shop Pay
  • Union Pay
  • Visa