{"product_id":"worcester-greenstar-24i-28i-junior-25si-30si-upmo-7m-pump-assembly-8716120409","title":"Worcester Greenstar 24i 28i Junior 25Si 30Si UPMO 7M Pump Assembly 8716120409","description":"\u003ch1\u003e\u003cspan\u003e\u003cstrong\u003eWorcester Greenstar 24i 28i Junior 25Si 30Si UPMO 7M Pump Assembly 8716120409\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003eWorcester Greenstar 24i 28i Junior 25Si 30Si UPMO 7M Pump Assembly 8716120409\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e is a water circulation component designed for use within selected Worcester Bosch Greenstar combi boiler systems. The pump assembly is responsible for circulating primary heating water through the boiler and supporting both central heating and domestic hot water operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eAs an important component within the boiler's hydraulic system, the \u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003eUPMO 7M pump assembly\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e supports effective water circulation, heat transfer and consistent appliance performance.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eℹ️ Product Condition Options:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis part may be available in \u003c\/span\u003e\u003cspan\u003e\u003cem\u003eNew\u003c\/em\u003e\u003c\/span\u003e\u003cspan\u003e or \u003c\/span\u003e\u003cspan\u003e\u003cem\u003eRefurbished\u003c\/em\u003e\u003c\/span\u003e\u003cspan\u003e condition. Please select your preferred option from the dropdown menu above. Refurbished units are professionally inspected and tested to help ensure reliable operation. Please verify compatibility before purchasing to ensure correct fitment.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003e\u003cstrong\u003eTechnical Insight \u0026amp; Common Failure Symptoms\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe pump assembly circulates primary heating water through the boiler's heat exchanger and hydraulic circuit, supporting efficient heat transfer during central heating and domestic hot water operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eTypical symptoms linked to a faulty pump assembly may include:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003ePoor or insufficient water circulation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eRadiators failing to heat up correctly\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eUnusual humming, vibrating or grinding noises\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eBoiler overheating due to inadequate water circulation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eIntermittent boiler shutdowns or lockouts\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eReduced or inconsistent heating and hot water performance\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eThese symptoms may also be caused by other hydraulic or electrical faults. Replacing a confirmed faulty pump assembly may help restore normal water circulation and appliance operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eYou can usually find pump troubleshooting information in:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eWorcester Bosch Technical Support\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eThe Worcester Bosch spare parts catalogue\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eYour boiler installation and servicing manual\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eBoiler fault code documentation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThis part (\u003c\/span\u003e\u003cspan\u003e\u003cstrong\u003eMPN: 8716120409\u003c\/strong\u003e\u003c\/span\u003e\u003cspan\u003e) is designed for selected models within the Worcester Bosch Greenstar Junior and Si combi boiler ranges. Please verify the part number against your boiler's technical manual before ordering to ensure correct fitment.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003e\u003cstrong\u003eSafety Advice\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003e\u003cem\u003eInstallation and servicing must be carried out by a suitably qualified Gas Safe registered engineer in accordance with the manufacturer's instructions and current regulations.\u003c\/em\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"Worcester","offers":[{"title":"Direct Sale","offer_id":51883691180135,"sku":"N9636-1","price":76.99,"currency_code":"GBP","in_stock":true},{"title":"Repair Service","offer_id":51883691212903,"sku":"N9636-2","price":61.99,"currency_code":"GBP","in_stock":true},{"title":"Advance Replacemnt","offer_id":51883691245671,"sku":"N9636-3","price":91.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0615\/0923\/8887\/files\/edited-photo-2026-11-27T114026.740_edc31565-785b-4333-878a-70c77b7dd18d.jpg?v=1795781104","url":"https:\/\/nationalboilerspares.co.uk\/products\/worcester-greenstar-24i-28i-junior-25si-30si-upmo-7m-pump-assembly-8716120409","provider":"National Boiler Spares","version":"1.0","type":"link"}