{"product_id":"worcester-boiler-printed-circuit-board-87161463050","title":"Worcester Boiler Printed Circuit Board 87161463050","description":"\u003ch1\u003e\u003cspan\u003eWorcester Boiler Printed Circuit Board 87161463050\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan\u003eProduct Overview\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eWorcester Boiler Printed Circuit Board (Part Number: 87161463050)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is an electronic ignition control component designed to manage and supervise burner ignition in suitable Worcester gas-fired boiler systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIdentified as the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eWorcester Ignition Control Board\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, this component forms part of the boiler's electronic ignition and combustion safety control system.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe PCB works alongside the boiler's ignition equipment, gas valve and associated safety devices to support the correct burner start-up sequence.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe board helps coordinate ignition-related functions, allowing the burner to operate when the required control and safety conditions are satisfied.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eℹ️ Product Condition Options:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis part may be available in \u003c\/span\u003e\u003cem\u003e\u003cspan\u003eNew\u003c\/span\u003e\u003c\/em\u003e\u003cspan\u003e or \u003c\/span\u003e\u003cem\u003e\u003cspan\u003eRefurbished\u003c\/span\u003e\u003c\/em\u003e\u003cspan\u003e condition. Please select your desired option from the dropdown menu above. Refurbished ignition control boards should be professionally inspected and tested to confirm correct electronic operation, ignition functionality and electrical safety before installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eTechnical Insight \u0026amp; Common Failure Symptoms\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe Worcester ignition control PCB is an electronic component responsible for supporting the boiler's burner ignition sequence and associated safety control functions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe board operates in conjunction with the boiler's control circuitry and ignition components. Electrical faults, damaged connections, moisture exposure or deterioration of internal electronic components may interfere with normal ignition operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003ePossible symptoms that may indicate an ignition PCB or associated component problem include:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eBoiler failing to ignite despite receiving a heating demand.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eBurner ignition sequence failing to begin or complete correctly.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIntermittent or unsuccessful burner ignition.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRepeated ignition failures or boiler safety lockouts.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIgnition spark failing to occur when required.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eBurner failing to establish a stable flame.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eBoiler shutting down during or shortly after an ignition attempt.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIncorrect or intermittent operation of ignition-related components.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eVisible damage, corrosion or deterioration affecting the PCB or its electrical connections.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eThese symptoms do \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003enot necessarily confirm a faulty ignition PCB\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, as similar problems may result from ignition electrodes, flame detection components, gas valves, electrical wiring, other control boards or associated combustion safety devices. Correct professional diagnosis should be carried out before replacing the unit.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eSafety Advice\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cem\u003e\u003cspan\u003eInstallation and servicing must be carried out by a suitably qualified Gas Safe registered engineer. Always isolate the gas and electrical supplies and follow the manufacturer's instructions.\u003c\/span\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cspan\u003eEnsure correct PCB compatibility, secure electrical connections and complete the required ignition, flame supervision and boiler safety checks before returning the appliance to service.\u003c\/span\u003e\u003c\/em\u003e\u003c\/p\u003e","brand":"WORCESTER","offers":[{"title":"New Other","offer_id":51743991791719,"sku":"N9034","price":74.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0615\/0923\/8887\/files\/Untitled-23_2026_._12.56.30.jpg?v=1795441005","url":"https:\/\/nationalboilerspares.co.uk\/products\/worcester-boiler-printed-circuit-board-87161463050","provider":"National Boiler Spares","version":"1.0","type":"link"}