{"product_id":"worcester-25cdi-30cdi-35cdi-40cdi-combi-boiler-burner-87180066580","title":"WORCESTER 25CDI 30CDI 35CDI 40CDI COMBI BOILER BURNER 87180066580","description":"\u003ch1\u003e\u003cspan\u003eWorcester 25CDi 30CDi 35CDi 40CDi Combi Boiler Burner 87180066580\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan\u003eProduct Overview\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eWorcester Bosch Boiler Burner (Part Number: 87180066580)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is a replacement combustion component designed for selected \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eWorcester Bosch\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e heating systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003ePart number \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e87180066580\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is identified as a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eBoiler Burner\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, forming part of the appliance's gas combustion and heat generation system.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe burner is responsible for supporting the controlled combustion of gas within the boiler. The heat generated during combustion is transferred through the boiler's heat exchanger to the heating water.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eCorrect burner operation is essential for reliable heat generation and safe boiler operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eℹ️ Product Condition Options:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis part may be available in \u003c\/span\u003e\u003cem\u003e\u003cspan\u003eNew\u003c\/span\u003e\u003c\/em\u003e\u003cspan\u003e or \u003c\/span\u003e\u003cem\u003e\u003cspan\u003eRefurbished\u003c\/span\u003e\u003c\/em\u003e\u003cspan\u003e condition. Please select your desired option from the dropdown menu above. Refurbished burners should be professionally inspected and tested to confirm their condition and suitability before installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eTechnical Insight \u0026amp; Common Failure Symptoms\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe boiler burner is a component of the combustion system, where the gas and combustion air mixture is ignited to generate heat.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe burner operates alongside the gas valve, ignition components, fan and boiler safety controls to support the appliance's normal combustion sequence.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eOver time, burner performance may be affected by contamination, corrosion, physical deterioration or damage to its combustion surfaces.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003ePossible symptoms that may indicate a burner or associated combustion system problem include:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eBoiler failing to ignite or fire correctly.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eBurner failing to establish or maintain a stable flame.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIntermittent burner operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIrregular combustion or flame behaviour.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eBoiler entering an ignition-related safety lockout.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eVisible corrosion, contamination or damage affecting the burner.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eBurner performance affected by restrictions or deterioration.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eThese symptoms do \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003enot necessarily confirm a faulty burner\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, as similar problems may result from ignition electrodes, gas valve faults, combustion airflow issues, electrical controls or other boiler components. Correct professional diagnosis should be carried out before replacement.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eCompatibility\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThis part (MPN: \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e87180066580\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e) is associated with selected \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eWorcester Bosch 25CDi, 30CDi, 35CDi and 40CDi\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e boiler systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003ePlease verify the exact boiler model, GC number, burner part number and appliance specifications against the manufacturer's technical documentation before ordering to ensure correct fitment.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eSafety Advice\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cem\u003e\u003cspan\u003eBoiler burners are safety-critical components within the appliance's gas combustion system. Inspection, removal and installation must only be carried out by a \u003c\/span\u003e\u003c\/em\u003e\u003cstrong\u003e\u003cem\u003e\u003cspan\u003eGas Safe registered engineer\u003c\/span\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003cem\u003e\u003cspan\u003e who is suitably qualified for the appliance and work being undertaken.\u003c\/span\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cspan\u003eAlways isolate the appliance and gas supply before carrying out any work and follow the manufacturer's installation and servicing instructions. The burner and associated combustion chamber seals must be correctly installed, and all required gas-tightness, combustion analysis, flue integrity and operational safety checks must be completed before the boiler is returned to service.\u003c\/span\u003e\u003c\/em\u003e\u003c\/p\u003e","brand":"WORCESTER","offers":[{"title":"New \/ New Other","offer_id":50538353197159,"sku":"N6593","price":189.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0615\/0923\/8887\/files\/aadc9425-b241-411a-88e4-d9af5bd2c07f_b9404d1c-af49-4a70-9a46-c49c3b5295e8.png?v=1792500623","url":"https:\/\/nationalboilerspares.co.uk\/products\/worcester-25cdi-30cdi-35cdi-40cdi-combi-boiler-burner-87180066580","provider":"National Boiler Spares","version":"1.0","type":"link"}