{"product_id":"vokera-eclipse-216-ess-226-ess-esc-boiler-gas-valve-10022441","title":"Sime Planet Dewy 60 BFR Boiler Gas Valve SIT 848 SIGMA 6243825","description":"\u003ch1\u003e\u003cspan\u003eSime Planet Dewy 60 BFR Boiler Gas Valve 6243825\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan\u003eProduct Overview\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eSime Planet Dewy 60 BFR Boiler Gas Valve (Part Number: 6243825)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is a gas control component designed to regulate the supply of gas to the burner in the Sime Planet Dewy 60 BFR boiler system.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIdentified as the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eSIT 848 SIGMA Gas Valve\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, this component forms part of the boiler's combustion control system, managing gas delivery according to the appliance's operating and safety requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe gas valve works alongside the boiler's electronic controls, ignition equipment and flame supervision components to ensure gas is supplied to the burner under the appropriate operating conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eDesigned for use within the boiler's premixed combustion system, the valve supports controlled gas delivery and regulation of the air-to-gas mixture during burner operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eℹ️ Product Condition Options:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis part may be available in \u003c\/span\u003e\u003cem\u003e\u003cspan\u003eNew\u003c\/span\u003e\u003c\/em\u003e\u003cspan\u003e or \u003c\/span\u003e\u003cem\u003e\u003cspan\u003eRefurbished\u003c\/span\u003e\u003c\/em\u003e\u003cspan\u003e condition. Please select your desired option from the dropdown menu above. Refurbished gas valves should be professionally inspected and tested to confirm correct operation, gas tightness and safety functionality before installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eTechnical Insight \u0026amp; Common Failure Symptoms\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe Sime SIT 848 SIGMA gas valve is an electrically controlled gas regulation component responsible for managing gas delivery to the boiler burner.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe valve operates in conjunction with the boiler's electronic control system and air-to-gas mixing assembly, supporting controlled burner ignition, stable combustion and safe shutdown.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eElectrical faults, internal valve deterioration, damaged connections or problems with gas pressure regulation may interfere with normal burner operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003ePossible symptoms that may indicate a gas valve or associated component problem include:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eBoiler failing to ignite despite receiving a heating demand.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eBurner failing to establish a flame during the ignition sequence.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIntermittent burner operation or unexpected shutdowns.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRepeated ignition failures or boiler safety lockouts.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eGas valve failing to open when correctly commanded.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIncorrect or unstable burner gas pressure.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eBurner failing to operate at the required output.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIrregular combustion or unstable burner operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eElectrical faults affecting the gas valve control circuit.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eVisible damage or deterioration affecting the valve housing or electrical connections.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eThese symptoms do \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003enot necessarily confirm a faulty gas valve\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, as similar problems may result from ignition electrodes, flame detection components, gas supply issues, fan operation, electrical wiring or control PCB faults. Correct professional diagnosis should be carried out before replacing the unit.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eSafety Advice\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cem\u003e\u003cspan\u003eInstallation and servicing must only be carried out by a suitably qualified Gas Safe registered engineer. Always isolate the gas and electrical supplies and follow the manufacturer's instructions.\u003c\/span\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cspan\u003eEnsure correct valve compatibility, secure gas and electrical connections, and complete the required gas tightness, gas pressure and combustion safety checks before returning the boiler to service.\u003c\/span\u003e\u003c\/em\u003e\u003c\/p\u003e","brand":"VOKERA","offers":[{"title":"New Other","offer_id":51786883465319,"sku":"N6573","price":109.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0615\/0923\/8887\/files\/edited-photo-2026-11-24T085245.367.jpg?v=1795510590","url":"https:\/\/nationalboilerspares.co.uk\/products\/vokera-eclipse-216-ess-226-ess-esc-boiler-gas-valve-10022441","provider":"National Boiler Spares","version":"1.0","type":"link"}