{"product_id":"vaillant-ecotec-plus-vu-gb-806-5-5-r2-boiler-fan-assembly-0020140756","title":"Vaillant Ecotec Plus VU GB 806\/5-5 R2 Boiler Fan Assembly 0020140756","description":"\u003ch1\u003e\u003cspan\u003eVaillant Ecotec Plus VU GB 806\/5-5 R2 Boiler Fan Assembly 0020140756\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan\u003eProduct Overview\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eVaillant Ecotec Plus Boiler Fan Assembly (Part Number: 0020140756)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is an electrically operated combustion component designed to manage airflow within suitable Vaillant gas-fired boiler systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe fan assembly forms part of the boiler's \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ecombustion and flue system\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, providing the controlled airflow required for burner ignition and combustion.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eWorking alongside the boiler's electronic control system, gas valve and associated combustion components, the fan supports the air-to-gas mixture required during burner operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe assembly helps maintain the airflow conditions necessary for controlled ignition, stable combustion and normal boiler operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eℹ️ Product Condition Options:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis part may be available in \u003c\/span\u003e\u003cem\u003e\u003cspan\u003eNew\u003c\/span\u003e\u003c\/em\u003e\u003cspan\u003e or \u003c\/span\u003e\u003cem\u003e\u003cspan\u003eRefurbished\u003c\/span\u003e\u003c\/em\u003e\u003cspan\u003e condition. Please select your desired option from the dropdown menu above. Refurbished fan assemblies should be professionally inspected and tested to confirm correct electrical operation, mechanical performance and safety functionality before installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eTechnical Insight \u0026amp; Common Failure Symptoms\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe Vaillant Ecotec Plus fan assembly is an electrically driven component responsible for providing the airflow required during the boiler's combustion process.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe fan operates in conjunction with the boiler's electronic control system, adjusting airflow according to operating requirements. Incorrect fan operation or insufficient airflow may prevent the boiler from completing its ignition sequence or maintaining normal burner operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eElectrical faults, worn motor bearings, damaged impeller components or deterioration of internal electrical connections may interfere with normal fan performance.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003ePossible symptoms that may indicate a fan assembly or associated component problem include:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eBoiler failing to ignite despite receiving a heating demand.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFan failing to start when required.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eUnusual grinding, rattling or humming noises during operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIntermittent or irregular fan operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFan running at an incorrect or inconsistent speed.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRepeated ignition failures or boiler safety lockouts.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eExcessive vibration during boiler operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eBurner failing to maintain stable combustion.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eUnexpected boiler shutdowns during operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eVisible damage or deterioration affecting the fan housing, motor or electrical connections.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eThese symptoms do \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003enot necessarily confirm a faulty fan assembly\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, as similar problems may result from electrical wiring faults, control PCB problems, restricted flue components, gas supply issues or other combustion control and safety devices. Correct professional diagnosis should be carried out before replacing the unit.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eSafety Advice\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cem\u003e\u003cspan\u003eInstallation and servicing must be carried out by a suitably qualified Gas Safe registered engineer. Always isolate the gas and electrical supplies and follow the manufacturer's instructions.\u003c\/span\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cspan\u003eEnsure correct fan compatibility, secure electrical and flue connections, and complete the required airflow, combustion and boiler safety checks before returning the appliance to service.\u003c\/span\u003e\u003c\/em\u003e\u003c\/p\u003e","brand":"VAILLANT","offers":[{"title":"New Other","offer_id":51791559393383,"sku":"N9629","price":297.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0615\/0923\/8887\/files\/edited-photo-2026-11-24T154826.381.jpg?v=1795535319","url":"https:\/\/nationalboilerspares.co.uk\/products\/vaillant-ecotec-plus-vu-gb-806-5-5-r2-boiler-fan-assembly-0020140756","provider":"National Boiler Spares","version":"1.0","type":"link"}