{"product_id":"ravenheat-rsf-82-84-100-csi-85-sit-ignition-pcb-0012gen05005-0","title":"RAVENHEAT RSF 82 84 100 CSI 85 SIT Ignition PCB 0012GEN05005\/0","description":"\u003ch1\u003e\u003cspan\u003eRAVENHEAT RSF 82 84 100 CSI 85 SIT Ignition PCB 0012GEN05005\/0\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan\u003eProduct Overview\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eRavenheat SIT Ignition Printed Circuit Board (Part Number: 0012GEN05005\/0)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is an electronic ignition control component designed to manage and supervise burner ignition in suitable Ravenheat gas-fired boiler systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIdentified as the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eSIT Printed Ignition Board – Blue Version\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, this component forms part of the boiler's ignition control system, supporting the ignition sequence and associated safety functions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe ignition PCB works alongside the boiler's main control board, gas valve and flame supervision components to coordinate burner ignition according to the appliance's operating requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eDesigned for \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eSIT Controls MK1 configurations\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, this component is associated with systems featuring a blue ignition control box mounted alongside the gas valve.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eℹ️ Product Condition Options:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis part may be available in \u003c\/span\u003e\u003cem\u003e\u003cspan\u003eNew\u003c\/span\u003e\u003c\/em\u003e\u003cspan\u003e or \u003c\/span\u003e\u003cem\u003e\u003cspan\u003eRefurbished\u003c\/span\u003e\u003c\/em\u003e\u003cspan\u003e condition. Please select your desired option from the dropdown menu above. Refurbished ignition PCBs should be professionally inspected and tested to confirm correct electronic operation, ignition functionality and electrical safety before installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eTechnical Insight \u0026amp; Common Failure Symptoms\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe Ravenheat SIT ignition PCB is an electronic control component responsible for supporting the burner ignition sequence and associated flame supervision functions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe board operates in conjunction with the boiler's control system to initiate ignition when the required operating conditions are satisfied. Faults affecting the ignition circuitry or associated electrical connections may prevent the burner from igniting correctly.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eElectrical faults, damaged connections, moisture exposure or deterioration of internal electronic components may interfere with normal ignition operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003ePossible symptoms that may indicate an ignition PCB or associated component problem include:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eBoiler failing to ignite despite receiving a heating demand.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eBurner ignition sequence failing to begin or complete correctly.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIntermittent or unsuccessful burner ignition.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRepeated ignition failures or boiler safety lockouts.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIgnition spark failing to occur when required.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eBurner failing to establish a stable flame.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eBoiler shutting down shortly after an ignition attempt.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIncorrect or intermittent operation of ignition-related components.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eVisible damage, corrosion or deterioration affecting the ignition PCB or its electrical connections.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eThese symptoms do \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003enot necessarily confirm a faulty ignition PCB\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, as similar problems may result from ignition electrodes, flame detection components, gas valves, electrical wiring, main control PCB faults or other combustion safety devices. Correct professional diagnosis should be carried out before replacing the unit.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eSafety Advice\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cem\u003e\u003cspan\u003eInstallation and servicing must be carried out by a suitably qualified Gas Safe registered engineer. Always isolate the gas and electrical supplies and follow the manufacturer's instructions.\u003c\/span\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cspan\u003eEnsure correct ignition PCB compatibility, secure electrical connections and complete the required ignition, flame supervision and boiler safety checks before returning the appliance to service.\u003c\/span\u003e\u003c\/em\u003e\u003c\/p\u003e","brand":"Ravenheat","offers":[{"title":"New Other","offer_id":51742993481831,"sku":"N7404","price":94.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0615\/0923\/8887\/files\/edited-photo-2026-11-23T112059.009.jpg?v=1795432866","url":"https:\/\/nationalboilerspares.co.uk\/products\/ravenheat-rsf-82-84-100-csi-85-sit-ignition-pcb-0012gen05005-0","provider":"National Boiler Spares","version":"1.0","type":"link"}