{"product_id":"potterton-performa-24eco-he-main-combi-24he-pcb-5112657-brand-new","title":"POTTERTON PERFORMA 24ECO HE \/ MAIN COMBI 24HE PCB 5112657 BRAND NEW","description":"\u003ch1\u003e\u003cspan\u003ePOTTERTON PERFORMA 24ECO HE \/ MAIN COMBI 24HE PCB 5112657 BRAND NEW\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan\u003eProduct Overview\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ePotterton Performa 24 Eco HE \/ Main Combi 24 HE Printed Circuit Board (Part Number: 5112657)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is an electronic control component designed to manage and supervise essential operating functions in compatible gas-fired boiler systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ePrinted Circuit Board (PCB)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e forms part of the boiler's main electronic control system, coordinating central heating, domestic hot water, ignition and safety-related operations.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe PCB processes signals from connected temperature sensors, thermostats and safety devices, allowing the boiler to respond to heating and hot water demands.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eWorking alongside the boiler's ignition equipment, gas valve and hydraulic components, the circuit board supports controlled burner operation, temperature regulation and normal boiler functionality.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eℹ️ Product Condition:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis part is supplied in \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eBrand New\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e condition. Please verify the manufacturer part number and boiler compatibility before purchasing or arranging installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eTechnical Insight \u0026amp; Common Failure Symptoms\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe Potterton and Main 5112657 printed circuit board is an electronic control unit responsible for coordinating the boiler's heating, domestic hot water and combustion control functions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe PCB receives signals from connected sensors and operating controls, processes heating demands and manages the activation of associated boiler components. It also monitors safety-related conditions and can interrupt boiler operation when the required operating conditions are not satisfied.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eElectrical faults, damaged connections, moisture exposure or deterioration of internal electronic components may interfere with normal boiler operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003ePossible symptoms that may indicate a printed circuit board or associated component problem include:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eBoiler failing to start despite receiving a heating demand.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eBoiler failing to ignite or complete its ignition sequence.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIntermittent or unexpected boiler shutdowns.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRepeated boiler lockouts or fault indications.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eCentral heating or domestic hot water failing to operate correctly.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eBoiler failing to respond to thermostat or control signals.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIncorrect or intermittent operation of connected boiler components.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eUnresponsive or irregular boiler control functions.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eVisible damage, corrosion or deterioration affecting the PCB or its electrical connections.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eThese symptoms do \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003enot necessarily confirm a faulty printed circuit board\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, as similar problems may result from defective sensors, ignition components, electrical wiring, thermostats, gas valves or other boiler control and safety devices. Correct professional diagnosis should be carried out before replacing the unit.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eSafety Advice\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cem\u003e\u003cspan\u003eInstallation and servicing must be carried out by a suitably qualified Gas Safe registered engineer. Always isolate the gas and electrical supplies and follow the manufacturer's instructions.\u003c\/span\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cspan\u003eEnsure correct PCB compatibility, secure electrical connections and complete the required electrical safety, ignition and boiler operational checks before returning the appliance to service.\u003c\/span\u003e\u003c\/em\u003e\u003c\/p\u003e","brand":"Potterton","offers":[{"title":"Genuine","offer_id":51834969030759,"sku":"N2331","price":99.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0615\/0923\/8887\/files\/edited-photo-2026-11-25T134505.704.jpg?v=1795614556","url":"https:\/\/nationalboilerspares.co.uk\/products\/potterton-performa-24eco-he-main-combi-24he-pcb-5112657-brand-new","provider":"National Boiler Spares","version":"1.0","type":"link"}