{"product_id":"hamworthy-hot-surface-ignitor-assy-wessex-220m-563801013","title":"Hamworthy HOT SURFACE IGNITOR ASSY WESSEX 220M 563801013","description":"\u003ch1\u003e\u003cspan\u003eHamworthy Hot Surface Ignitor Assy Wessex 220M 563801013\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan\u003eProduct Overview\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eHamworthy Hot Surface Ignitor Assembly (Part Number: 563801013)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is an electrical ignition component designed for selected \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eHamworthy Wessex 220M commercial gas boilers\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, including the Wessex 220M HE range.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIdentified as a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eHot Surface Ignitor (HSI) Probe Assembly\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, this component forms part of the boiler's burner ignition system, providing the heat required to ignite the gas-air mixture during the burner start-up sequence.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eUnlike a conventional spark electrode, the hot surface ignitor uses an \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eelectrically heated ignition element\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e that reaches a temperature sufficient to initiate combustion when the appropriate gas-air mixture is supplied.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe ignitor operates alongside the boiler's electronic combustion controls, gas valve and flame supervision system to support controlled burner start-up and safe ignition.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eIts ignition element and insulating components are designed for operation within the high-temperature environment of the burner assembly.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eCorrect operation is essential for maintaining reliable burner ignition, consistent boiler start-up and safe, controlled combustion.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eℹ️ Product Condition Options:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThis part may be available in \u003c\/span\u003e\u003cem\u003e\u003cspan\u003eNew\u003c\/span\u003e\u003c\/em\u003e\u003cspan\u003e or \u003c\/span\u003e\u003cem\u003e\u003cspan\u003eRefurbished\u003c\/span\u003e\u003c\/em\u003e\u003cspan\u003e condition. Please select your desired option from the dropdown menu above. Refurbished hot surface ignitor assemblies should be professionally inspected and tested to confirm their condition, correct operation and suitability for installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eTechnical Insight \u0026amp; Common Failure Symptoms\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eHamworthy Hot Surface Ignitor 563801013\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is responsible for providing the heated ignition surface required to establish burner combustion. It operates in conjunction with the boiler's ignition control system, which energises the ignitor during the appropriate stage of the burner start-up sequence.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eDeterioration of the heating element, damaged ceramic insulation, incorrect positioning, electrical connection faults or contamination affecting the ignition surface may interfere with normal heating and reliable burner ignition.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003ePossible symptoms that may indicate a faulty hot surface ignitor or associated ignition system problem include:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eBoiler failing to ignite despite receiving an operating demand.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eBurner failing to establish a flame during the ignition sequence.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRepeated ignition attempts or unsuccessful burner start-up.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eBoiler entering an ignition-related safety lockout.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIgnitor failing to heat when the appropriate electrical supply is applied.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIntermittent ignition or inconsistent burner start-up.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eOpen-circuit or abnormal electrical resistance readings identified during professional testing.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eVisible cracks, fractures or deterioration affecting the ignition element.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eDamaged ceramic insulation or electrical connections.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eIgnition element showing signs of excessive wear, contamination or overheating.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eThese symptoms do \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003enot necessarily confirm a faulty hot surface ignitor\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, as similar problems may result from the electrical supply, ignition controls, wiring, gas valve, gas supply, burner condition or flame supervision components. Correct professional diagnosis should be carried out before replacing the component.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eSafety Advice\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cem\u003e\u003cspan\u003eHot surface ignitor assemblies are essential ignition components within gas-fired commercial heating appliances. Inspection, removal, installation and testing must only be carried out by a \u003c\/span\u003e\u003c\/em\u003e\u003cstrong\u003e\u003cem\u003e\u003cspan\u003eGas Safe registered engineer\u003c\/span\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003cem\u003e\u003cspan\u003e who is suitably qualified for the appliance and work being undertaken.\u003c\/span\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cspan\u003eAlways isolate the appliance's gas and electrical supplies before carrying out any work and follow the manufacturer's installation and servicing instructions.\u003c\/span\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cspan\u003eEnsure the correct \u003c\/span\u003e\u003c\/em\u003e\u003cstrong\u003e\u003cem\u003e\u003cspan\u003eignitor part number, appliance model, electrical specification and installation position\u003c\/span\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003cem\u003e\u003cspan\u003e are verified before installation. Similar hot surface ignitors may have different operating characteristics or mounting arrangements.\u003c\/span\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cspan\u003eHot surface ignitors can reach \u003c\/span\u003e\u003c\/em\u003e\u003cstrong\u003e\u003cem\u003e\u003cspan\u003eextremely high temperatures during operation\u003c\/span\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003cem\u003e\u003cspan\u003e. Allow the component and surrounding burner assembly to cool completely before handling. Never touch the ignition element while energised or immediately after operation.\u003c\/span\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003c\/em\u003e\u003cstrong\u003e\u003cem\u003e\u003cspan\u003eignition element and ceramic insulation are fragile\u003c\/span\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003cem\u003e\u003cspan\u003e and must be handled carefully to prevent cracks, fractures or damage during installation. Follow the manufacturer's instructions for mounting, positioning and electrical connections.\u003c\/span\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cspan\u003eNever bypass, modify or disable the boiler's ignition safety controls or flame supervision system.\u003c\/span\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cspan\u003eAppropriate \u003c\/span\u003e\u003c\/em\u003e\u003cstrong\u003e\u003cem\u003e\u003cspan\u003eignitor operation testing, ignition sequence verification, flame supervision checks and combustion safety checks\u003c\/span\u003e\u003c\/em\u003e\u003c\/strong\u003e\u003cem\u003e\u003cspan\u003e must be completed before returning the boiler to service.\u003c\/span\u003e\u003c\/em\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003e\u003cspan\u003eIf repeated ignition failures, electrical damage or unsafe burner operation are suspected, do not operate the appliance until it has been inspected by a suitably qualified professional.\u003c\/span\u003e\u003c\/em\u003e\u003c\/p\u003e","brand":"Hamworthy","offers":[{"title":"New Other","offer_id":51624429846631,"sku":"N7526","price":109.99,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0615\/0923\/8887\/files\/2062846.jpg?v=1794823643","url":"https:\/\/nationalboilerspares.co.uk\/products\/hamworthy-hot-surface-ignitor-assy-wessex-220m-563801013","provider":"National Boiler Spares","version":"1.0","type":"link"}